[NO.1] [NO.2] [NO.3] [NO.4] [NO.5] [NO.6]
     
   
  Dongri Brand normal pressure water boiler,steam boiler
   
  Dongri Brand normal pressure water boiler,steam boiler
  I.Brief introduction
  Dongri Brand normal pressure water boiler and steam boiler is the honored product by Dongri Thermal Energy Equipment Co.,Ltd which is also deely trusted by customers. It has won nation level prizes for many times.It is made with imported stainless steel.In design,reinforced thermal energy conversion technology which is internationally advanced is adopted.Quality assurance system is observed strictly in the course of production and installation.Therefore this series of products have a long service life,high thermal efficiency and reliable quality.

Dongri Brand normal pressure fuel oil water boiler and steam boiler consists of two series,a dozen of varieties,suitable for residence,apartment, ,hotel,sauna,hospital,school,factory,army and farm,is the ideal equipment for getting hot water,boiled water and steam.

mation
  II.Superior characteristics
  Safety:Dongri Brand water boiler is normal pressure boiler.Thanks to no pressure in the course of running,its safety properties are high,and it is not monitored by labor safety departments and need for certificated boiler worker to operate this equipment.
 
Normal pressure water boiler,steam boiler
 
 
  Reliability:The water boiler adopts stainless steel material,combustor and control components are imported from famous manufacturers after strict inspection and selection.The process from raw materials purchase,design to production and after-sales service is controlled strictly by quality assurance system,so the quality of this product is obviously superior to any other manufacturer.
Superiority:Dongri Brand water boiler adopts advanced and unique design structure and special technologies,which make its thermal efficiency attain over 87%.Energy-saving ,no vibration in operation, low noise,full combustion and lampblack pollution elimination.The advanced micro-computer automatically-controled system conducts automatic control over waterlevel,temperature,running of combustor and timing start/stop and so on.Dismantable combination structure make check and maintenance more convenient.
Economical:Dongri Brand water boiler adopts vertical structure,occupy small space,save land and construction cost.The adoption of unique design structure improves thermal efficiency and reduces fuel consumption.The adoption of the automatic intelligent controlling system reduces labor tension of the workers and running cost,and the improvement of safety and reliability reduces maintenance expenditure every year.
  III.Working principle of the system
 
  Working principle of the water heating system
 
1. In the set time,cold water is taken in,at the same time water boiler heat the water.After the cold water is heated in the water boiler,it flow into the water tank.When the water level in the water tank reachs the set water level,cold water feed punp stop working.
2. In the set time,when the temperature of the water in the water tank is lower than the set temperature, the cycle pump starts working,exhaust the low temperature water in the water tank into the water boiler to be heated again and again.When the temperature of the water in the water tank reaches the set temperature, the cycle pump and water boiler stop working.
3. In the set time,pressured backwater pump work to return low temperature water in the hot water pipe to the water boiler to be heated again,and send the hot water to the part where hot water is consumed.Open hot water valve,hot water will flow out.
4. When oil level in the oil level tank is lower than the set level,gear oil pump work to exhaust oil.When oil level in the oil level tank reaches the set oil level,it stops working.
  Working principle of water boiling system
 
1. Cold water enter water boiler via water compensating tank.When water level in the boiler reaches the set water level, the float ball valve in the water compensating tank is closed to stop water from entering.
2. In the set time,water boiler work to boil the water.When the temperature in the boiler is lower than 100C,the electromagnetic valve is closed,the boiler goes on boiling water.The system goes on cycling like this.After the boiling tank is full,the electromagnetic valve is closed, and water boiler stops working.Open the boiled water valve,boiled water will flow out.
  Workign principle of steam boiler system
 
1. In the set time,when water level in the steam boiler is lower than the set water level,cold water feed pump work to exhaust water,when the water level reaches the set level,it stops working.
2. In the set time,the seteam boiler work to produce steam.The steam first enter the steam dividing cylinder,then is sent to all the parts where steam is consumed via all steam pipes.

  IV.Technical specifications of Dongri fuel oil boiler
 
Hot and boiled water boiler :
 
DRL-1-1.5 DRL-1-3.5 DRL-1-6 DRL-1-11 DRL-1-16 DRL-1-22A
Standard calorific capacity for water output
(kacl/h)
15000 35000 60000 110000 160000 220000
Water output temperature ( 60-100
Water output (kg/h) 500-200 1150-500 2000-850 3650-1570 5300-2280 7300-3100
Fuel oil combustor Diesel consumption
(kg/h)
1.75±10% 4.0±10% 7.2±10% 13.2±10% 19.6±10% 26.5±10%
pneumatic power (W) 75 90 117 170 170 370
Voltage
(V/50Hz)
220/380 220/380 220/380 220/380 220/380 220/380
Fuel gascombustor Liquified gas consumption
(m3/h)
2.1 5.0 8.7 15.9 23.2 32.0
pneumatic power (W) 50 50 90 117 370 370
Voltage
(V/50Hz)
220 220 220 220 220 220
Working pressure (kg/cm3  
Size of boiler body (mm) φ452×1220 φ500×1506 φ600×1650 φ760×2000 φ920×2440 φ1020×2440
  蒸汽炉Steam boiler :
 
DRL-1-1.5 DRL-1-3.5 DRL-1-6 DRL-1-11
Standard calorific capacity for water output
(kacl/h)
15000 35000 60000 110000
Oil consumption (kg/h) 1.7±10% 3.9±10% 6.8±10% 12.4±10%
Steam output temperature ( 100-105
Suitable sauna volume
(m3
18 42 72 132
Rice steamed capacity (kg) 20-50 50-100 75-150 135-250
Number of dining people
(人)
20-250 200-5000 300-750 500-1250
Size of boiler body(mm) φ4520×1300 φ500×1500 φ600×1650 φ755×1900
Max.working pressure
(kg/cm2
≤1
   
 
 
 