Repair & maintenance
 
1. Drain off dirt regualrly according to water quality,usually once every month,Clean inside of heat collector,dredge dirt water nozzle of the heat collector and let dirt water flow out automatically.
2. Clean the water tank once every month,let dirt water flow out of the dirt drainage valve.
3. Remove the dust on the glass of the heat collector regularly lest it influence thermal efficiency.
  Common breakdowns and solutions(As per Picture 8)
   
 
Serial no. Problem Cause Solution
1 Overflow of water tank a. The valve core of the float ball valve is choked or the plastic is broken
b. Water pressure is too high
c. Ball check valve is invalid,and cold water flow into hot water pipe.
a.Change valve,plastic ring and valve core
b.Install a ball valve on the water in-take pipe to reduce water intake flow
c.Change a new ball check valve
2 Heat water outlet is not smooth

a. Water flow into the water fetch float ball and the float ball sink to the bottom of the water tank.
b. Float ball valve and water fetch float ball are choked.
c. Part of the pipe is in a higher place
d.The pipe is choked by something
e.The diameter of hot water outlet pipe is too small.

a.Change a new water fetch float ball
b.Open the observation hole to repair
c.Remove the higher part or add an automatic air exhaust valve.
d.Remove the dirt.
e.Enlarge the diameter of the pipe.

3 Low water temperature

a.The water in the water tank is not full in time
b.The water level inthe water tank is lower than the upper cycle opening.
c.The sunlight is low in strength, the heat collector is covered away from sunlight.
d.The accumulated dust onthe glass is too thick.

a.Fill the tank with water before 8AM.
b.Adjust the position of the float ball to ensure the upper cycle opening is lower than the water level.
c.The heat collector should be lighted fully.
d.Remove the dust on the glass.
4
Water can't be heated when using electricity to heat water.
a.Defective contact between connecting end and electric heating pipe.
b.The electric heating pipe is damaged and the power is cut off automatically.
a.Change a new connector or press tightly the connector on the end of the wire.s
b.Change a new electric heating pipe.
5 Temperature of the water is lower than the set value when using electricity to heat water. a.The heating time is no t enough
b.The scale of the temperature controller is not accurate.
a.Go on heating
b.Change a new temperature controller or adjust the temperature scale to a higher point to prolong heating time.
   
 
   
All rights reserved by Dongguan Dongri Thermal Energy Equipment Co.,Ltd
Add:Tangbei,Guan-tai Road,Dongguan City,Guangdong,China Tel:0769-22410118 22410668 Fax:0769-22480708
 Email:webmaster@dongrichina.com